Combination of chest compressions and interposed abdominal compressions in a swine model of ventricular fibrillation - 06/06/16

Doi : 10.1016/j.ajem.2016.02.008 
Marios Georgiou, CCRN a, b, Elizabeth Papathanassoglou, PhD c, d, Nicos Middleton, PhD c, Apostolos Papalois, PhD e, Theodoros Xanthos, PhD f, g,
a American Medical Center Cyprus, Nicosia, Cyprus 
b Cyprus Resuscitation Council, Nicosia, Cyprus 
c Department of Nursing, School of Health Sciences, Cyprus University of Technology, Limassol, Cyprus 
d Faculty of Nursing, University of Alberta, Edmonton, AB, Canada 
e ELPEN Research Experimental Center, Athens, Greece 
f School of Medicine, European University of Cyprus, Nicosia, Cyprus 
g Hellenic Society of Cardiopulmonary Resuscitation, Athens, Greece 

Corresponding author at: 89 Patision Av., 10434, Athens, Greece. Tel.: +30 2110121756; fax: +30 2110121758.89 Patision Av.Athens10434Greece

Abstract

Purpose

The aim of this study was to investigate the effects of the combination of chest compressions and interposed abdominal compressions (IAC-CPR) in a swine model of ventricular fibrillation (VF).

Methods

Twenty healthy female Landrace-Large White pigs were the study subjects. At the end of the eighth minute of VF, animals in the control group (Group A) received chest compressions at a rate of 100/min, while animals in the experimental group received chest compressions and simultaneous interposed abdominal compressions (CC-IAC – Group B), both at a rate of 100/min. The primary end point of the experiment was return of spontaneous circulation (ROSC). Secondary outcomes were 48-h survival rate and 48-h neurologic outcome.

Results

Six animals (60%) from Group A and 9 animals (90%) from Group B achieved ROSC (P=.121). There was a statistically significant difference in systolic aortic pressure, mean aortic pressure, right atrial pressures, and end-tidal carbon dioxide (ETCO2) between the two groups during the first cycle of CPR, while during the second cycle, diastolic aortic pressure was significantly higher in Group B. Coronary perfusion pressure (CPP) values in group B were significantly higher compared with those in Group A during the first and second cycle of CPR. Neurologic examination was statistically significantly better in Group B (75.00±10.00 vs. 90.00±10.00, P=.037).

Conclusion

ROSC did not differ statistically significant in the IAC-CPR compared to the CPR group only, while CPP was significantly higher in IAC-CPR–treated animals.

Le texte complet de cet article est disponible en PDF.

Plan


 Source of support: Cyprus Resuscitation Council.


© 2016  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 34 - N° 6

P. 968-974 - juin 2016 Retour au numéro
Article précédent Article précédent
  • Bedside sonographic measurement of optic nerve sheath diameter as a predictor of intracranial pressure in ED
  • Erdal Komut, Nalan Kozac?, Bedriye Müge Sönmez, Fevzi Y?lmaz, Seval Komut, Zeliha Nilgün Y?ld?r?m, ?nan Beydilli, Cihat Yel
| Article suivant Article suivant
  • Early neurologic examination is not reliable for prognostication in post–cardiac arrest patients who undergo therapeutic hypothermia
  • Michael S. Merrill, Catherine M. Wares, Alan C. Heffner, Kenneth L. Shauger, H. James Norton, Michael S. Runyon, David A. Pearson

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.