S'abonner

Patency of the Viabahn stent graft for the treatment of outflow stenosis in hemodialysis grafts - 24/02/16

Doi : 10.1016/j.amjsurg.2015.12.006 
Jorge Carmona, M.D. a, , Yevgeniy Rits, M.D. b, Brandt Jones, D.O. c, Larry Dowers, B.S. c, Donna Bednarski, R.N. b, Jeffrey R. Rubin, M.D. b
a Department of General Surgery, Wayne State University/Detroit Medical Center, Detroit, MI, USA; University Health Center, 4201 St. Antoine, Detroit, MI 48201, USA 
b Department of Vascular Surgery, Cardiovascular Institute at Detroit Medical Center, Detroit, MI, USA 
c Department of Vascular Surgery at Detroit Medical Center, Detroit, MI, USA 

Corresponding author. Tel.: 787-363-4502; fax: 313-745-1873.

Abstract

Background

To evaluate arteriovenous graft patency when failing grafts are treated with Viabahn covered stents vs percutaneous angioplasty (PTA) alone.

Methods

A retrospective review of all patients that underwent endovascular interventions for failing grafts at a single institution between January 2010 and July 2013 was performed. Forty-four patients were identified who were treated with PTA alone (11) and with Viabahn stent grafts (33) for stenoses in the venous to graft anastomoses. Patient demographics, procedural success, and intraoperative complications were recorded as well as graft patency at 3, 6, and 12 months. Graft patency was reviewed and compared with PTA alone.

Results

There was no statistically significant difference between the 2 groups regarding gender, frequency of diabetes, hypertension, coronary artery disease, or peripheral arterial disease. Primary technical success defined as residual stenosis 10% or less was achieved in 100% of the cases. Follow-up was determined by flow velocities during dialysis and ultrasound imaging in the vascular laboratory. At 12 months 87.8% (29/33) grafts with stents were functional vs 36.4% (4/11) of those with PTA alone. Primary patency of the stent group was 61%, 52%, and 42% at 3, 6, and 12 months respectively vs the PTA group 64%, 45%, and 9%.

Conclusions

Grafts treated with Viabahn covered stents for outflow stenosis have a superior patency to PTA alone, 12 months after treatment; although earlier post treatment results are comparable.

Le texte complet de cet article est disponible en PDF.

Keywords : Arteriovenous graft, Arteriovenous fistula, Primary patency, Assisted primary patency, Secondary patency


Plan


 There were no relevant financial relationships or any sources of support in the form of grants, equipment, or drugs.


© 2016  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 211 - N° 3

P. 551-554 - mars 2016 Retour au numéro
Article précédent Article précédent
  • Life after hyperthermic intraperitoneal chemotherapy; measuring quality of life and performance status after cytoreductive surgery plus hyperthermic intraperitoneal chemotherapy
  • Jennifer Ford, Michael Hanna, Anna Boston, Richard Berri
| Article suivant Article suivant
  • The impact of tree-stand falls on a Level 1 trauma center in West Michigan
  • Joseph T. Carroll, Alistair J. Chapman, Alan T. Davis, Carlos H. Rodriguez

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.