S'abonner

Efficacy and Safety of Paclitaxel-Coated Balloon for the Treatment of In-Stent Restenosis in High-Risk Patients - 13/11/15

Doi : 10.1016/j.amjcard.2015.08.041 
Marco Miglionico, MD, Fabio Mangiacapra, MD, PhD , Annunziata Nusca, MD, PhD, Domenico Scordino, MD, Paolo Gallo, MD, PhD, Cosimo Marco Campanale, MD, Rosetta Melfi, MD, Germano Di Sciascio, MD
 Department of Cardiovascular Sciences, Campus Bio-Medico University, Rome, Italy 

Corresponding author: Tel: (+39) 06-225411612; fax: (+39) 06-225411638.

Abstract

In-stent restenosis (ISR) is a major cause of failure of percutaneous coronary intervention. The efficacy and safety of drug-coated balloon (DCB) in patients with high-risk clinical features are largely unknown. We enrolled 82 consecutive patients at high risk of bleeding with angiographically significant (diameter stenosis ≥50%) ISR of bare metal stent (BMS) or drug-eluting stent (DES), treated with paclitaxel-coated balloon. All patients presented at least one of the following criteria: high bleeding risk, neoplasm, chronic inflammatory disease, and need for noncardiac surgery. Dual antiplatelet therapy was indicated for 4 weeks after the procedure. At angiographic follow-up, overall late lumen loss was 0.24 ± 0.32 mm, with no significant difference between BMS-ISR and DES-ISR (0.25 ± 0.35 vs 0.22 ± 0.30 mm, p = 0.714). The Kaplan-Meier estimate for major adverse clinical events-free survival at 3 years was 81.4% (82.3% in BMS-ISR vs 79.4% in DES-ISR, log-rank p = 0.866). No stent thrombosis has been recorded. In conclusion, the use of paclitaxel-coated balloon seems to be associated with favorable outcomes after percutaneous coronary intervention for BMS-ISR or DES-ISR in patients with high-risk clinical features and could be considered as a reasonable option in the presence of systemic co-morbidities and contraindications to long-term dual antiplatelet therapy.

Le texte complet de cet article est disponible en PDF.

Plan


 See page 1693 for disclosure information.


© 2015  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 116 - N° 11

P. 1690-1694 - décembre 2015 Retour au numéro
Article précédent Article précédent
  • Relation Between Monocyte to High-Density Lipoprotein Cholesterol Ratio With Presence and Severity of Isolated Coronary Artery Ectasia
  • Harun Kundi, Murat Gok, Emrullah Kiziltunc, Mustafa Cetin, Hulya Cicekcioglu, Zehra Guven Cetin, Orhan Karayigit, Ender Ornek
| Article suivant Article suivant
  • Immediate and Long-Term Results of Drug-Eluting Stents in Mammary Artery Grafts
  • Iñigo Lozano, Ana Serrador, Ramon Lopez-Palop, Garikoitz Lasa, Jose Moreu, Eduardo Pinar, Armando Perez de Prado, Fernando Alfonso, Manuel Jimenez Navarro, Monica Fernandez Quero, Javier Pineda, Javier Martin Moreiras, Koldobika Garcia San Roman, Jose R. Lopez Minguez, Alfonso Suarez Cuervo, Antonio Gutierrez, Felipe Hernandez, Jose A. Baz, Amparo Benedicto, Jose R. Rumoroso, Joan A. Gomez-Hospital, Vicens Serra, Jose M. de la Torre, Valeriano Ruiz-Quevedo, Javier Botas, Jose A. Fernandez, Angel Sanchez-Recalde

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.