M. Guiraudou a, b, L. Maimoun e, J.-M. Dumas b, M. Julia d, I. Raingeard c, J.-F. Brun a, , b
a Inserm U1046, CNRS UMR9214, « physiologie et médecine expérimentale du cœur et du muscle », université de Montpellier, 34090 Montpellier, France 
b Équipe d’exploration métabolique (CERAMM), département de physiologie clinique, hôpital Lapeyronie, 34295 Montpellier cedex 5, France 
c Équipe d’endocrinologie, diabétologie, nutrition, hôpital Lapeyronie, CHU de Montpellier, 34295 Montpellier, France 
d Fédération de médecine du sport, hôpital Lapeyronie, CHU de Montpellier, Montpellier, France 
e Service de médecine nucléaire, hôpital Lapeyronie, CHRU de Montpellier, 391, avenue du Doyen-Giraud, 34295 Montpellier cedex 5, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 1
Vidéos 0
Autres 0

Résumé

Introduction

La bio-impédancemétrie (BIA) perd en précision chez les athlètes très minces ou très lourds à cause de limitations du modèle traditionnel qui assimile le corps à un cylindre. Ces limitations sont corrigées par un modèle plus proche de la réalité anatomique, utilisé par la BIA segmentaire.

Synthèse des faits

Nous avons testé un nouveau dispositif utilisant cette approche, le Biacorpus RX4000 (Healthnesslink, France), que nous avons validé d’abord contre la DEXA et ensuite utilisé chez une équipe de rugbymen. La validation chez 96 sujets couvrant un éventail de IMC 13–48kg/m2 a montré pour la masse grasse (MG) une concordance remarquable (r=0,988 ; erreur moyenne 0,532 [95 % intervalle de confiance, IC : −0,495 ; 1,56]) avec DEXA. La composition de chaque segment est prédite avec précision (r=0,823–0,958). Dans une équipe de 29 rugbymen (âge : 18–31ans ; indice de masse corporelle moyen : 29 [allant de 21 à 41kg/m2]), nous avons trouvé un % moyen de masse grasse de 18,46 %, la masse musculaire étant en moyenne du double de la masse grasse. Alors que ni la masse musculaire mesurée avec BIA, ni la BCM n’étaient prédictifs des mesures de performance de sprint, le temps de 10m en sprint était fortement corrélé à la masse grasse (r=0,738, p<0,01) et au pourcentage de masse grasse (r=0,750, p<0,01). De même le temps mis à effectuer le test de sprints répétés de Gacon 45-15 était corrélé à la masse grasse (r=0,783, p<0,01) et au % FM de masse grasse (r=0,693, p<0,01).

Conclusion

Ainsi, cette technique nouvelle de BIA segmentaire fournit une détermination plus précise de la masse maigre et de la masse grasse chez les sujets minces et obèses, et fournit des mesures fortement corrélées avec la performance au sprint et au test de Gacon chez les rugbymen, mettant en évidence l’effet négatif d’un excès de masse grasse sur cette performance.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

We previously reported highly significant correlations between body cell mass (BCM) measured by BIA and aerobic capacity in rugby players. However, BIA loses precision in slim or heavy athletes due to limitations of the model that are overcome with segmental BIA.

Synthesis of the facts

We tested a new device using this approach, the RX4000 Biacorpus (Healthnesslink, France), that we validated first against DEXA and then applied to a team of rugby players. Validation in 96 subjects covering a range of BMI 13–48kg/m2 showed for fat mass (MG) a remarkable agreement (r=0.988; average error 0.532 [95% confidence interval, CI: −0.495; 1.56]) with DEXA. The composition of each segment is accurately predicted (r=0.823–0.958). In a team of 29 rugby players (age: 18–31yr; mean body mass index 29 (ranging from 21–41kg/m2), we found an average % of fat mass of 18,46% and muscle mass was on the average two-fold bigger than fat mass. However, neither muscle mass nor BCM measured with BIA were predictor of measurements of sprint performance, while the time of 10m sprint was strongly correlated to fat mass (r=0.738, P<0.01) and to % fat mass (r=0.750, P<0.01) as did the time to perform Gacon's 45-15 repeated sprint test (FM r=0.783, P<0.01; % FM r=0.693, P<0.01).

Conclusion

Thus, this new segmental BIA technique provides a markedly improved determination of fat and fat free mass in lean and obese subjects and provides measurements strongly correlated with sprint and repeated test performance in rugby players, emphasizing the negative effect of excess fat mass on this performance.

Le texte complet de cet article est disponible en PDF.

Mots clés : Masse maigre, Impédancemétrie bio-électrique, Absorptiométrie biphotonique (DEXA), Impédancemétrie segmentaire

Keywords : Fat-free mass, Bioelectrical impedance analysis, Dual-energy X-ray absorptiometry, Segmental BIA


Plan


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 30 - N° 5

P. 298-302 - octobre 2015 Retour au numéro
Article précédent Article précédent
  • Relationships between power outputs measured from force-velocity test, Optojump test and Five-jump test in male shot putters
  • M. Landolsi, L. Labiadh, F. Zarrouk, P. Lacouture, Z. Tabka
| Article suivant Article suivant
  • Effects over one year of low-intensity endurance exercise targeted at the level of maximal lipid oxidation
  • M. Guiraudou, C. Fédou, A.-J. Romain, A. Sferlazza, E. Calas, J.-F. Brun

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.