S'abonner

Clinical value of relative quantification ultrasound elastography in characterizing breast tumors - 12/10/15

Doi : 10.1016/j.biopha.2015.08.029 
Alfonso Fausto a, Domenico Rubello b, , Alice Carboni c, Paola Mastellari b, Sotirios Chondrogiannis b, Luca Volterrani a, b, c
a Department of Diagnostic Imaging, Azienda Ospedaliera Universitaria Senese, Policlinico Universitario ‘Santa Maria alle Scotte’, Viale Bracci 16, 53100 Siena, Italy 
b Department of Radiology, Nuclear Medicine, Medical Physics, Head Service of Nuclear Medicine, PET/CT Centre, ‘Santa Maria della Misericordia Hospital’, Via Tre Martiri 8, 45100 Rovigo, Italy 
c Department of Medical, Surgical and Neuro Sciences, Diagnostic Imaging, University of Siena, Strada delle Scotte 2, 53100 Siena, Italy 

Corresponding author at: Department of Nuclear Medicine, PET/CT Oncologic Centre, Radiology, Diagnostic and Interventional Senology, Interventional Radiology, NeuroRadiology, Medical Physics, Laboratory, Tumoral Biomarkers, Pathology, Microbiology Santa Maria della Misericordia Hospital, Rovigo, Via Tre Martiri 140, 45100 Rovigo, Italy. Fax: +39 425 39 4434.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 4
Vidéos 0
Autres 0

Abstract

Objectives

To evaluate ultrasound elastography (USE) using strain ratio (SR), a relative quantification approach for breast lesions characterization.

Methods

One hundred forty-seven consecutive patients with a total of 156 breast lesions underwent USE. Technical accuracy was assessed automatically. For SR evaluation a rounded ROI was depicted inside fat (F), glandular tissue (G) and inside the lesion (L), preferably at the same depth. R1, mean value of the G and F ratio, stands for in background tissue composition elasticity. R2; mean value of L/F stands for in lesion elasticity, both evaluated in arbitrary unit (au). Two-years follow-up and pathology results were standard of reference. Mann–Whitney test, ROC analysis and Chi-square with Yates correction were used.

Results

With the exception of 27 cysts, 17 malignant and 112 benign lesions were found. R1 values were 1.6±0.7au and 1.2±0.9au (p=0.015 NS); R2 values were 6.1±2.5au and 1.9±1.3au (p<0.001) for malignant and benign lesions, respectively. A threshold of 3.3au showed a sensitivity and specificity of 88% and 87%, respectively with an AUC of 93%. Fifteen false positive and two false negative were detected.

Conclusion

Relative quantification of ultrasound elastography allows to find high levels of diagnostic accuracy in characterizing breast tumors above all in downgrading BI-RADS 3 and 4 lesions.

Le texte complet de cet article est disponible en PDF.

Keywords : Breast neoplasm, Tissue characterization, Ultrasound, Elastography, Strain ratio


Plan


© 2015  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 75

P. 88-92 - octobre 2015 Retour au numéro
Article précédent Article précédent
  • Prognostic value of PD-1 and TIM-3 on CD3+ T cells from diffuse large B-cell lymphoma
  • Li Zhang, Hui Du, Tai-wu Xiao, Ji-zhu Liu, Guo-zhen Liu, Jing-xia Wang, Guang-yao Li, Le-xin Wang
| Article suivant Article suivant
  • Benzophenone derivatives as cysteine protease inhibitors and biological activity against Leishmania(L.) amazonensis amastigotes
  • Letícia de Almeida, Karina Ferreira Alves, Claudia Mara Maciel-Rezende, Larissa de Oliveira Passos Jesus, Francieli Ribeiro Pires, Claudio Viegas Junior, Mario Augusto Izidoro, Wagner Alves de Souza Júdice, Marcelo Henrique dos Santos, Marcos José Marques

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.