S'abonner

Subtrochanteric femoral fractures treated with the Long Gamma3® nail: A historical control case study versus Long trochanteric Gamma nail® - 06/10/15

Doi : 10.1016/j.otsr.2015.06.018 
D. Georgiannos , V. Lampridis, I. Bisbinas
 424 Military General Hospital, Peripheriaki Odos Efkarpias, PC 56429, Thessaloniki, Hellas, Greece 

Correspondence author. Tel.: +30 2310 381000; fax: +30 2313 059007.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Gamma nail was developed for the treatment of subtrochanteric hip fractures. Despite its advantages over extramedullary devices, gamma nail has been historically related to significant complications (implant breakage, femoral fractures at the tip of the nail). There is limited data to determine if the rate of these complications was minimized by using a new design of the gamma nail. Therefore we performed a case control study between the long gamma3 nail (LG3N) and the long trochanteric gamma nail (LTGN) to assess if: (1) the complication rate in the treatment of subtrochanteric fractures using the LG3N was lower than the one using the LTGN; (2) the reoperation rate was lower after using the LG3N.

Hypothesis

The complication rate after fixation of subtrochanteric fracture of the femur is lower with LG3N than with the LTGN.

Patients and methods

This study prospectively recorded the intra- and postoperative complications of 75 patients with subtrochanteric fractures treated with the LG3N and compared them with those of a historical cohort of 83 patients treated with the LTGN. The two groups were matched regarding age, gender and fracture type. Patients with open, pathological, or impending fractures were excluded.

Results

Intraoperative complications in the LG3N group were lower (4 cases, 5.3%) compared with those in the LTGN group (9 cases, 10.8%; P=0.04). The major intraoperative complication encountered with the use of LTGN was fracture of the femur in 3 cases. We encountered in total 9 postoperative complications in LG3N (12%) and 20 in group LTGN (24%). The most frequent complication in both groups was the cut out of the lag screw (3 cases in LG3N and 7 cases in LTGN group). The overall reoperation rate was higher in LTGN group (20.4% vs 10.6%; P=0.03).

Conclusion

As a result of the improvement of its mechanical characteristics, LG3N has proved a safe and efficient implant for the treatment of subtochanteric fractures. The new design seems superior to previous generation, giving promising outcomes, reduced mechanical complication rates, and reduced reoperation rate.

Level of evidence

Level III – case controlled study.

Le texte complet de cet article est disponible en PDF.

Keywords : Subtrochanteric fractures, Gamma3 nail, Intramedullary nailing, Complications


Plan


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 6

P. 675-680 - octobre 2015 Retour au numéro
Article précédent Article précédent
  • Primary cup stability in THA with augmentation of acetabular defect. A comparison of healthy and osteoporotic bone
  • F. Amirouche, G. Solitro, S. Broviak, W. Goldstein, M. Gonzalez, R. Barmada
| Article suivant Article suivant
  • Influence of preoperative factors on the gain in flexion after total knee arthroplasty
  • G. Pasquier, B. Tillie, S. Parratte, Y. Catonné, J. Chouteau, G. Deschamps, J.-N. Argenson, M. Bercovy, J. Salleron

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.