S'abonner

Primary cup stability in THA with augmentation of acetabular defect. A comparison of healthy and osteoporotic bone - 06/10/15

Doi : 10.1016/j.otsr.2015.07.007 
F. Amirouche a, , G. Solitro a, S. Broviak a, W. Goldstein a, b, M. Gonzalez a, R. Barmada a
a Department of orthopaedics, university of Illinois at Chicago, 835, S. Wolcott avenue, 60616 Chicago, Illinois, USA 
b Illinois bone and joint institute, 9000, Waukegan road, 60053 Morton Grove, Illinois, USA 

Corresponding author. Department of orthopaedics, university of Illinois at Chicago, 835, S. Wolcott avenue, room E270, 60612 Chicago, IL, USA. Tel.: +312 996 7161; fax: +312 996 9025.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background context

Reconstruction of acetabular defect has been advocated as standard procedure in total hip arthroplasty. The presence of bony defects at the acetabulum is viewed as a cause of instability and acetabular wall augmentation is often used without proper consideration of surrounding bone density. The initial cup-bone stability is, however, a challenge and a number of studies supported by clinical follow-ups of patients suggested that if the structural graft needs supporting more than 50% of the acetabular component, a reconstruction cage device spanning ilium to ischium should be preferred to protect the graft and provide structural stability. This study aims to (1) investigate the relationship between cup motion and bone density and (2) quantify the re-distribution of stress at the defect site after augmentation.

Hyphotesis

Paprosky type I or II, acetabular defects, when reconstructed with bone screws supported by bioabsorbable calcified triglyceride bone cement are significantly less effective for osteoporotic bone than healthy bone.

Materials and methods

Acetabular wall defects were reconstructed on six cadaveric subjects with bioabsorbable calcified triglyceride bone cement using a re-bar technique. Data of the specimen with higher bone density was used to validate a Finite Element Model. Values of bone apparent density ranging from healthy to osteoporotic were simulated to evaluate (1) the cup motion, through both displacement and rotation, (2) and the von Mises stress distribution.

Results

Defect reconstruction with bone screws and bioabsorbable calcified triglyceride bone cement results in a re-distribution of stress at the defect site. For a reduction of 65% in bone density, the cup displacement was similar to a healthy bone for loads not exceeding 300N, as load progressed up to 1500N, the reconstructed defect showed increase of 99μm (128%) in displacement and of 0.08° in rotation angle.

Conclusions

Based on the results, we suggest that an alternative solution to wall defect augmentation with bone screws supported by bioabsorbable calcified triglyceride bone cement, be used for osteoporotic bone.

Level of evidence

Level IV, experimental and cadaveric study.

Le texte complet de cet article est disponible en PDF.

Keywords : Arthroplasty, Replacement, Hip prosthesis, Bone cements, Osteoporosis


Plan


 This work was partially supported by Aurelio M. Caccomo family foundation.


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 6

P. 667-673 - octobre 2015 Retour au numéro
Article précédent Article précédent
  • Excellent short-term results of hip resurfacing in a selected population of young patients
  • A. Lons, A. Arnould, T. Pommepuy, E. Drumez, J. Girard
| Article suivant Article suivant
  • Subtrochanteric femoral fractures treated with the Long Gamma3® nail: A historical control case study versus Long trochanteric Gamma nail®
  • D. Georgiannos, V. Lampridis, I. Bisbinas

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.