The body weight–walking distance product as related to lung function, anaerobic threshold and peakO2in COPD patients - 02/09/11

Doi : 10.1053/rmed.2001.1115 
M.-L. CHUANG a, f1, I.-F. LIN b, K. WASSERMAN c
a Division of Pulmonary and Critical Care Medicine, Chang Gung Memorial Hospital, Taoyuan, Taiwan 
b Department of Social Medicine, National Yang Ming University Taipei, Taiwan, R.O.C. 
c Division of Respiratory and Critical Care Physiology and Medicine, Department of Medicine, Harbor-UCLA Medical Center, Torrance, CA, 90509, U.S.A. 

Abstract

The product of walking distance and body weight (D·W) mimics the work of walking. We hypothesized the superiority of D·W to walking distance (D) alone in any correlation with lung function, anaerobic threshold (AT) and maximal oxygen uptake (O2max). We further hypothesized that the D·W product for a 6-min walk test (6 MWT) would correlate with the AT andO2maxbecause all three are markers of exercise ability.

Thirty-three male chronic obstructive pulmonary disease (COPD) patients with mean forced expiratory volume in 1 sec (FEV1) of 1·2±0·4 l (range 0·58–1·86 l) were enrolled. Six patients were excluded due to inability to achieve a maximal test. Lung function and self-assessed every-day activities using a oxygen–cost diagram were evaluated before entry of the study. A maximal effort ramp-pattern cardiopulmonary exercise test (CPET) and a 6 MWT were conducted in random order. Borg score, heart rate, and O2saturation with pulse oximetry (SPO2) were measured during both exercise tests.O2AT and minute ventilation were also measured during the CPET. Correlations were sought between the distance covered in the 6 MWT, and the D·W product with AT,O2maxand other variables.

The average D and D·W were 456 m and 27·5 kgkm−1, respectively. D·W was superior to D alone when correlated with theO2maxand AT determined from the CPET, while modestly correlated with the change (Δ) in Borg score and ΔSpO2in the 6 MWT and self-assessed every-day activities. Distance×weight product was correlated with the AT andO2max. In addition, D·W was better correlated with diffusing capacity for carbon monoxide and vital capacity than D alone.

We conclude that D·W mimics the work of walking better than D and is suggested as a parameter for evaluation of patients' fitness if gas exchange measurements are not available.

Le texte complet de cet article est disponible en PDF.

Keywords : 6-min walking test, cycle ergometer, Borg score, oxygen–cost diagram, AT.



© 2001  Harcourt Publishers Ltd. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 95 - N° 7

P. 618-626 - juillet 2001 Retour au numéro
Article précédent Article précédent
  • A comparison of surfactant delivery with conventional mechanical ventilation and partial liquid ventilation in meconium aspiration injury
  • S.E. CHAPPELL, M.R. WOLFSON, T.H. SHAFFER
| Article suivant Article suivant
  • Changes in asthma drug therapy costs for patients receiving chronic montelukast therapy in the U.K. : Volume 95, pp. 83-89
  • D.B. PRICE, R.H. BEN-JOSEPH, Q. ZHANG

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.