S'abonner

Global longitudinal strain: a novel index of left ventricular systolic function - 25/08/11

Doi : 10.1016/j.echo.2004.02.011 
Shimon A Reisner, MD a, , Peter Lysyansky, PhD b, Yoram Agmon, MD a, Diab Mutlak, MD a, Jonathan Lessick, MD, DSc a, Zvi Friedman, PhD b
a Department of Cardiology, Rambam Medical Center, Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel 
b GE Ultrasound, Tirat HacarmelIsrael (P.L., Z.F.) 

*Reprint requests: Shimon A. Reisner, MD, Department of Cardiology, Rambam Medical Center, Haifa 31096, Israel

Abstract

Background

Echocardiographic estimation of global left ventricular (LV) function is subjective and time consuming. Our aim was to develop a novel approach for assessment of global LV function from 2-dimensional echocardiographic images

Methods

Novel computer software for tissue tracking was developed and applied as follows: digital loops were acquired from apical 2-, 3-, and 4-chamber views and a line was loosely traced along the LV endocardium at the frame wherein it was best defined. Around this line, the software selected natural acoustic markers moving with the tissue. Automatic frame-by-frame tracking of these markers during the heart cycle yielded a measure of contractility along the selected region of interest. Global longitudinal strain (GLS) and GLS rate (GLSR) were calculated for the entire U-shaped length of LV myocardium (basal, mid, and apical segments of 2 opposite walls in each view). To test this software, computer-derived GLS and GLSR were analyzed by a nonechocardiographer, blinded to the echocardiographic interpretation, in 27 consecutive patients after myocardial infarction (MI) (age 64.4 ± 12.9 years; 19 men; mean wall-motion score index of 1.79 ± 0.44) and compared with those obtained in 12 consecutive control patients (age 59.0 ± 9.7 years; 8 women), with a normal echocardiographic study.

Results

GLS and GLSR, averaged from the 3 apical views, differed significantly in patients post-MI compared with control patients (GLS −14.7 ± 5.1% vs −24.1 ± 2.9% and GLSR −0.57 ± 0.21/s vs −1.02 ± 0.09/s for patients post-MI vs control patients, respectively; both P < .0001). There was a good linear correlation between the wall-motion score index and the GLS and GLSR (R = 0.68 and R = 0.67, respectively; both P < .0001). A cut-off value for GLS of −21% had 92% sensitivity and 89% specificity and a cut-off value for GLSR −0.9/s had 92% sensitivity and 96% specificity for the detection of patients post-MI.

Conclusions

GLS and GLSR are novel indices for assessment of global LV function from 2-dimensional echocardiographic images. Early validation studies with the method are suggestive of high sensitivity and specificity in the detection of LV systolic dysfunction in patients post-MI.

Le texte complet de cet article est disponible en PDF.

Plan


© 2004  American Society of Echocardiography. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 17 - N° 6

P. 630-633 - juin 2004 Retour au numéro
Article précédent Article précédent
  • Effect of central hypothyroidism on Doppler-derived myocardial performance index
  • Fabio Luiz Casanova Doin, Mariana da Rosa Borges, Orlando Campos, Antonio Carlos de Camargo Carvalho, Angelo Amato Vincenzo De Paola, Marcelo Goulart Paiva, Julio Abucham, Valdir Ambrosio Moises
| Article suivant Article suivant
  • Tachycardia during the valsalva maneuver: a sign of normal diastolic filling pressures
  • Calin V Maniu, Rick A Nishimura, A.Jamil Tajik

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.