S'abonner

Arthrodesis simulation orthosis, an alternative to surgical ankle arthrodesis in ankle osteoarthritis on walking pain by using the methodology of SCED - 26/09/17

Doi : 10.1016/j.rehab.2017.07.003 
Isabelle Loiret, Noël Martinet, Jean Paysant, Guillaume Bokobza , Anne-Gabrielle François
 Institut régional de réadaptation, centre Louis-Pierquin, Nancy, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Objective

Ankle osteoarthritis (AO) is a usual long-term complication of ankle trauma. Pain during walking is the main symptom limiting walking distance. Non-surgical treatment including drugs, corticosteroid intra-articular injection or orthosis, could be used to decrease pain. The gold standard treatment of end stage of AO is the definitive surgical ankle arthrodesis. The purpose of this study is to prove the effectiveness of the hind foot stabilisation orthosis called “arthrodesis simulation” (AS) on the walking-pain and walking distance in a population suffering from ankle and/or hind foot osteoarthritis.

Material/patients and methods

A single case experimental design (SCED) with a structure (A1-B1-A2-B2) used randomly repeated measurements of a 2MWT to determine changes at each phase of the study. Pain at the end of the 2MWT using a visual analogue scale and the walking distance were evaluated by a blind assessor. One patient from Regional Rehabilitation Institute in Nancy (IRR, France) suffering from AO and wearing an AS daily, walked at fast speed during the 2MWT without AS during the 2 baseline phases (A1, A2) and with AS during the 2 intervention phases (B1, B2). Visual analysis, mean, trend and nonoverlap of all pairs (NAP) were calculated for both values for each phase.

Results

The average pain was significantly different between each phase (A1-B1-A2-B2) (Wilcoxon test). The pain NAP was 100% which corresponds to all data points assessing pain were greater during walking without AS. The pain trend increased with the measurement time without AS whereas the pain trend was stable, close to 0, with AS. The average walking distance was significantly different between each phase (A1-B1-A2-B2) (t-test). The walking distance NAP was close to 100% corresponding to all data points assessing walking distance were greater with AS. The walking distance trend increased faster with AS compared to without AS.

Discussion, conclusion

This SCED demonstrated the effectiveness of the AS on walking-pain and walking distance in people suffering from AO. Wearing AS increased walking distance during 2MWT without pain. Further SCEDs are necessary to confirm AS efficiency. This device, which is an orthopaedic treatment, could be an interesting alternative to surgical ankle arthrodesis.

Le texte complet de cet article est disponible en PDF.

Keywords : Arthrodesis simulation orthosis, Ankle osteoarthritis, Walking pain, SCED


Plan


© 2017  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 60 - N° S

P. e33 - septembre 2017 Retour au numéro
Article précédent Article précédent
  • Rehabilitation's importance in cervico brachial neuralgia management
  • Wafa Haj Hamad, Mouna Sghir, Aymen Haj Salah, Wafa Said, Wassia Kessomtini
| Article suivant Article suivant
  • Outcomes and evaluation in upper limb amputees
  • Isabelle Loiret, Rémi Leclaire, Noël Martinet, Jean Paysant

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.